Tests and investigations on masonry

Single and double flat jacks, endoscopies, sonic surveys, radar surveys, tests on bedding mortars.

For the characterisation of masonry, aimed for example at the design of static or anti-seismic consolidation works, the following types of investigation are available, which in fact coincide with those indicated by the current technical standards for construction.

 

ENDOSCOPIC INVESTIGATION

The endoscopic investigation allows for an in-depth investigation of the composition of the masonry, its consistency, the nature of the materials that make it up (mortar-stone adherence) and to identify any cavities, internal cracks or anomalies.

The test consists of drilling a hole in the masonry with a maximum diameter and depth determined during the planning stage. Following thorough cleaning of the hole, the endoscopic probe is inserted, proceeding slowly, with inspection of the interior of the element under investigation, and the acquisition of photographic and video images to record what has been found.

Tasq has high-resolution wireless endoscopes with an articulated probe to guarantee the best possible endoscopic performance.

 

RADAR INVESTIGATION

The availability of antennas of a suitable frequency makes it possible to carry out investigations of the wall composition aimed at qualifying the content of internal cavities. Radar inspection before and after a consolidation operation by injection, for example, makes it possible to assess its homogeneity and therefore its effectiveness. Please refer to the “Radar Surveys” section of this website for more details.

 

TESTS WITH SINGLE AND DOUBLE JACKS

Tests with flat jacks make it possible to assess the existing stress regime and the mechanical characteristics of the masonry in situ; in particular:

  • the test with single flat jacks allows the estimation of the existing vertical stress state (compression tension in service);
  • the test with double flat jacks allows estimation of the elastic modulus and the value of the resistance to failure (availability of the entire load-displacement curve).

Prior to carrying out both types of test, in the area identified for the purpose, the shape and size of the blocks of which the masonry is made are identified in order to identify the test location required to carry out a representative test. The test operations are briefly described below.

 

Single flat jack test

The test consists of making a cut in the masonry and applying a known pressure to the internal surfaces of the same, in order to restore the initial deformation conditions.

Beforehand, special calibrated plates are attached to the masonry, straddling the cut, which are used to measure displacements by means of a digital millesimal deformometer. Alternatively, the use of inductive displacement transducers is possible. A circular hydraulic cutting machine is then used to make a masonry cut in which a semi-oval flat jack (dim. 350x260x4 mm) is inserted. The compression present in the masonry causes the cut to close again immediately after its execution; the injection of a low-viscosity fluid inside the jack makes it possible to bring the cut edges back to the original distance, at which it is possible to read the fluid pressure, correlated, with appropriate corrective factors, to the tensional state present in the masonry.

 

Test with double flat jacks

The test consists of making two parallel cuts in the masonry and applying a known pressure to the internal surfaces of these cuts in order to reproduce a state of tension similar to uniaxial in the portion of masonry between the jacks.

Firstly, two horizontal cuts are made at a distance of approximately 50 cm from each other, using a circular hydraulic cutting machine. Two flat semi-oval jacks (dim. 350x260x4 mm) are inserted into them.

Subsequently, special calibrated plates are fixed to the masonry, in the space between the two jacks, which are used to measure displacements by means of a digital millesimal deformometer. Alternatively, the use of inductive displacement transducers is possible.

By increasing the pressure of the hydraulic fluid in the jacks and reading the displacements at the same time, the pressure-displacement curve for the masonry can be obtained with the use of appropriate correction factors; from this it is possible to deduce the elastic moduli (initial and secant) of the masonry and its resistance to fracture.

Tasq has hydraulic equipment for the accurate and calibrated execution of the masonry cuts; this is a maximum guarantee of the quality of the load-displacement curve even at small deformations (initial section of the curve). New, certified flat jacks are also used for each test.

 

SONIC INVESTIGATIONS

Sonic investigations, like ultrasonic investigations, are based on measuring the time-of-flight (TOF) of elastic waves within a body. The mechanical-acoustic impulse is introduced into the medium through an instrumented hammer and detected remotely by a receiver probe (accelerometer). This testing methodology allows the detection of internal defects (cavities, cracks), the degree of homogeneity, the qualitative assessment of the effectiveness of diffuse injection interventions, and the evaluation of the length and defectiveness of foundation piles.

The sonic investigations are carried out with constant use of an oscilloscope in order to guarantee the highest quality of the determinations.

 

MORTAR PENETROMETRIC INVESTIGATIONS

The method is based on the relationship between the penetration depth of a special nail and the compressive strength of the mortar. A nail with a diameter of 3.5mm and a length of 40mm is driven by a preloaded spring (constant energy at each stroke) into the mortar joint, through the use of a hand-held tool. Following the extraction of the nail and the cleaning of the hole by means of a rubber pump, the use of a centesimal dial gauge allows for the measurement of the nail’s driving depth. The test is performed with instrumentation and test methods conforming to ASTM C803.

Approfondimenti