Crumbling for hollow core slabs or the detachment of portions of intrados plaster from existing slabs is an event that has recently been a major occurrence.
Since January 2012, Tasq technicians have been developing a protocol for verifying the risk of crumbling for hollow core slabs and detachment of intrados plaster for slabs of different types.
The following are the investigation phases envisaged for a complete check, specifying that their sequence may be limited to the initial phases if they are already significant.
In relation to the types of floor and a cost-benefit analysis that Tasq is able to provide to the client, it is possible to plan the investigation campaign or adapt it during execution according to technical and economic optimisation criteria.

PHASE 1: ACQUISITION OF HISTORICAL FLOOR DATA
The diagnostic activity on existing floors is facilitated by the retrieval of any possible information regarding their type, with particular reference to:
- date of construction
- type of floor: for example, in the 60s and 70s, there was a proliferation of construction types with more or less marked reciprocal differences (Rome-type floors, Trirex floors, …). Even in cases where the type of floor is not mentioned in any document, the comparison between the geometry measured on site and the library of historical data held by Tasq makes it possible in many cases to identify the type of floor present.
- current and past use, both in relation to loads and thermo-hygrometric conditions.
PHASE 2: PRELIMINARY VISUAL SURVEY
The availability of even very sophisticated survey instruments and the frequent eagerness to accelerate their use must never be allowed to disregard an accurate visual investigation of the ceilings.
In this specific case, the investigation makes use of close observations of the surfaces, with the possible aid of techniques typical for painted surfaces. At this stage, it is possible to detect any vicissitudes suffered by the intrados plaster of a ceiling, such as the presence of interruptions, lacerations, repairs.
Tasq’s frequent activity in the field of cultural and architectural heritage facilitates the migration of experience and technique from these areas to those of hospital, school and industrial construction.
PHASE 3: INSTRUMENTAL INVESTIGATION BY MEANS OF ACTIVE INFRARED THERMOGRAPHY
With a view to applying the ‘best science’ and ‘best technique’ to the problems under examination, a preliminary investigation by means of thermography is envisaged, with the following two aims
- identification of the cracking framework;
- identification of plaster detachments.
In particular, an “active” type of investigation is envisaged, involving the creation of a thermal stress on the surfaces to be investigated. This energy input can be achieved by means of air heaters (convection heating) or radiation (lamps). Passive thermography, i.e. without any thermal stress, can only detect such data approximately and with low resolution due to the presence of incidental and uncontrollable thermal gradients.
The thermographic survey is only able to investigate the surface layers of an artefact; it is therefore only thanks to the different conductivities and thermal inertia of the building elements in depth that the thermal imaging camera will be able to map temperatures on the surface.
PHASE 4: POSSIBLE LOCALISED TESTS
On the basis of the data obtained in the previous phases, we proceed, if necessary, with the execution of local intradossal tests to verify the type of floors present. In the event that historical data is available and thermography has revealed the presence of uniformity in the texture and type, the number of surveys may be limited to the verification of what is already known.
PHASE 5: DIFFUSE SONIC INVESTIGATION
A prior complete beating of the intradossal surface of the floors is envisaged by means of hammers of different masses and composition operated manually and, if necessary, with the use of recoil rods. In this way it is possible, also on the basis of previous thermographic investigations, to obtain an initial detachment map to be checked subsequently with instrumental methods.
PHASE 6: DETAILED SONIC SURVEY
The verification of breakthroughs will be carried out, if deemed necessary, by means of sonic investigation for which, during percussion with known energy, the sound return will be detected on the surfaces by means of a microphone station. Starting from the representation of sound in the time domain, the frequency spectrum is evaluated (Cartesian diagram showing frequencies in Hz on the x-axis and the corresponding decibel levels on the y-axis).
To this end, spectrum analysers currently used for seismic accelerometer acquisitions will be used, therefore with resolution, sampling frequency and AD conversion filters that are completely exuberant for the application in this specific case.
Acquisition hardware and software. Acquisition hardware and processing software programmed on a LabView platform directly by Tasq technicians is used for this purpose. Included are signal processing functions for audio measurements, fraction-of-octave analysis, frequency analysis, transient analysis and order tracking.
Thrust system. A push system with constant impact energy, for maximum repeatability, by means of a spring-loaded rod with a spring mass release system at the end of the stroke. A hard rubber head allows uniform impact on the surface. The striking device provides for contact on the surface to be investigated by the striking head only, with no need for foreign elements that could alter the sonic responses.
Sonic acquisition system. The sonic acquisition system consists of a professional unidirectional microphone.
Extensive calibration of the instrumentation on fully known defect cases allows the instrumentation to be assigned a high degree of reliability.

PHASE 7: LOCAL ENDOSCOPIC INVESTIGATIONS
In areas where thermographic and sonic investigations reveal the presence of damage/detachment and therefore the danger of cracking, endoscopic investigations can be carried out to assess any cracking lines within the pinions.
Tasq has high-definition wireless video endoscopes with an articulated probe.
PHASE 8: REPRESENTATION OF CRACKS AND HAZARD MAPS
The preceding operations are aimed at returning to the client graphic tables with the representation of the “DAMAGE AND DANGER MAPS” on which the same may plan any consolidation interventions.
The minimum content of the graphic tables includes:
- Identification of the direction of the warping of the floors and reporting of any discrepancies in the texture of the same or with respect to any existing project tables.
- Tracing of the cracking framework, with graduation according to the different degrees of crack opening (max. 3 subdivisions envisaged);
- Damage and danger map for the phenomenon of cracking, intended both as detachment of the plaster from the support, and as internal cracking of the walls of the hollow flooring block.
A technical test report including photographic documentation is always foreseen.


QUALIFICATION AND CERTIFICATION OF OPERATORS
Tests are always performed with the presence and supervision of a structural engineer with CICPND (Italian Certification Centre for Non-Destructive Testing and Industrial Processes) certification at level 3 (maximum) for slab buckling tests.
See for this purpose the “Company Certifications” section of the site.