GENERAL

Load tests consist of experimentally verifying the behaviour and performance of a structural element under service or collapse actions.
They may be aimed at testing, to verify correspondence with design predictions, or they may be carried out to analyse and verify a structural element already in place whose static performance is unknown.
In the latter case, the judgement on the capacity of the structures to safely support a certain load does not involve the simple application of that load or an equivalent load. In fact, it is necessary to be able to judge how the load is supported by the structural element in order to ensure that we are sufficiently far from collapse conditions (factor of safety). To this end, tests are carried out involving the application of numerous load cycles, with the possibility of determining certain parameters (repeatability, linearity and permanence) adopted as an index of the static potential of the structural elements themselves.
Prior to the execution of the test, Tasq always plans to carry out an on-site inspection. This allows:
– to choose the test method (with ballasts, with jacks, …);
– to calculate in advance through appropriate calculation models, including numerical models for finished elements, the load to be materialised;
– to choose the most appropriate execution method (monotonic increasing load test, cyclic test, …);
– to verify the boundary conditions in logistic terms.
The main types of load tests that can be carried out are described below, without being exhaustive.

 

LOAD TESTS WITH HYDRAULIC JACKS (pull/push on floors or other structural elements)

This type of test involves the application on structural elements of any type of one or more localised loads through the use of one or more hydraulic jacks suitably opposed to a system of chains and tensioners anchored to support structures already in place or suitably constructed.
The entity of the point loads is determined in such a way as to induce the same maximum expected stresses on the structural element.
The test consists of the application of a gradually increasing load up to the predetermined limit, possibly with incremental cyclic repetition.
The displacements and/or rotations of the tested structural element are measured in real time during the execution of the test, through the use of displacement transducers, the use of high-precision optical measurements, and the use of inclinometers.

 

LOAD TEST WITH BALLAST WEIGHTS

In this type of test, as an alternative to the use of hydraulic jacks, suitably dimensioned and applied ballasts can be used.
For structural floor elements (floors and beams), for example, a uniformly distributed load can be materialised by means of water tanks (rigid or flexible) or by the use of uniform arrangements of heavy material. The test consists of the application of the load in increasing steps until the maximum design stresses are reached and the subsequent unloading. The methods and timing associated with this type of test often make it difficult to apply several loading and unloading cycles (cyclic load test).
The displacements and/or rotations of the tested structural element are measured in real time throughout the test, through the use of displacement transducers, the use of high-precision optical measurements, and the use of inclinometers.

 

LOAD TESTS ON PARAPETS

This type of test involves the application on the parapet to be tested of one or more concentrated loads statically equivalent to the design linear load laid down by the reference technical standards. The loads are generally materialised by means of a hydraulic jacking system.
During the execution of the test, the displacements of the structure are measured in real time in order to assess its elastic behaviour and the reversibility of the displacements when the load is cancelled.
For parapets, it is Tasq’s practice to carry out: a detailed geometric survey of the parapet, finite element modelling of the same with a load equal to that prescribed by law, and recalculation of the same in order to identify the statically equivalent load layout.

 

LOAD TESTS ON BRIDGES

Load tests on bridges generally involve the application of loads by means of vehicles (trucks, …) with known characteristics and load and verified with weighing coupons. In some cases, the exclusive or supplementary use of mobile ballasts (water tanks, inert material, …) is possible. The positioning of the loads and their sequence of application are agreed in advance with the construction management and/or the tester of the work.
The deformation evolution of the bridge deck, acquired throughout the course of the test, is detected through the use of displacement transducers, the use of high-precision optical measurements, and the use of inclinometers.

 

LOAD TESTS ON FOUNDATION PILES

Load tests on foundation piles make it possible to determine the load-bearing capacity of individual piles under operating or collapse conditions. Both tests on pilot piles, in order to determine the load-displacement curve up to collapse, and tests on piles intended for permanent operation can be carried out.
The test consists of the application of a progressively increasing load, possibly also with the introduction of load cycles, by means of hydraulic jacks counteracted on ballasts or on contrasting structures built ad hoc.
The displacements are measured by means of displacement sensors at the pile head with all the necessary precautions to be able to discount the effects of thermal variations and ground surface subsidence around the pile.